MKCM type OIL SIGNAL
 |
[ Flow rate with a switch ]
to detect the flow of fluid, it is turned ON or OFF the switch at your specified flow rate
※ switch is fixed (can not be set value changes later) [ flow is visible at a glance ] transparent tube of a galvanometer to check the flow of fluid in the movement of the float [ with protective cover ] by the metal protective cover the possibility of damage due to impact or the like from the outside and reduce. [Mounting orientation does not matter ] attitude of when mounting because it uses a spring inside is you can do up and down and sideways, etc. freely.
|
Model List
Model |
Dimensions (mm) |
Flow rate (L / min) |
Port size |
full length |
Full width |
Depth |
Minimum inside diameter
φmm |
Specified range of operating flow rate |
maximum |
MKCM20-1TL-OFF |
Rc1 / 8 |
80 |
Thirty |
twenty two |
6.5 |
0.005 (5cc) ~ 2 |
Five |
MKCM20-1TL-ON |
MKCM20-2TL-OFF |
Rc1 / 4 |
80 |
Thirty |
twenty two |
6.5 |
0.005 (5cc) ~ 2 |
Five |
MKCM20-2TL-ON |
MKCM20-3TL-OFF |
Rc3 / 8 |
86 |
Thirty |
twenty five |
6.5 |
0.005 (5cc) ~ 2 |
Five |
MKCM20-3TL-ON |
MKCM30-2TL-OFF |
Rc1 / 4 |
104 |
43 |
32 |
9.5 |
0.05 (50cc) ~ 5 |
Ten |
MKCM30-2TL-ON |
MKCM30-3TL-OFF |
Rc3 / 8 |
104 |
43 |
32 |
9.5 |
0.05 (50cc) ~ 5 |
Ten |
MKCM30-3TL-ON |
MKCM30-4TL-OFF |
Rc1 / 2 |
110 |
43 |
32 |
9.5 |
0.05 (50cc) ~ 5 |
Ten |
MKCM30-4TL-ON |
MKCM35-4TL-OFF |
Rc1 / 2 |
124 |
49 |
44 |
13.5 |
1.0 to 10 |
twenty five |
MKCM35-4TL-ON |
MKCM35-6TL-OFF |
Rc3 / 4 |
124 |
49 |
44 |
13.5 |
1.0 to 10 |
twenty five |
MKCM35-6TL-ON |
MKCM45-6TL-OFF |
Rc3 / 4 |
142 |
62 |
Fifty |
18.0 |
3.0 to 15 |
Fifty |
MKCM45-6TL-ON |
MKCM45-8TL-OFF |
Rc1 |
142 |
62 |
Fifty |
18.0 |
3.0 to 15 |
Fifty |
MKCM45-8TL-ON |
|
When ordering, quote □ Please specify the inside of.
Model
MKCM □□ - □ TL-OFF (ON) |
Oil of type □
(or the viscosity of the oil□ CSt) |
Operating flow rate of the switch□ L / Min |
Example: MKCM20-2TL-OFF oil types ISOVG32 operating flow rate 1L / min of switch ※ contact method Please specify the is OFF method or the ON system. Contact is OFF when the OFF mode, the fluid does not flow (normally open · A contact) contact is ON when the ON system, fluid does not flow (normally closed · B contact)
Standard specification
fluid |
oil |
Operating flow rate |
Above, please specify at a flow rate value within the specified range of operating flow rate.
(Please specify as much as possible in the one-third or less of the flow rate value of the minimum flow rate used.) |
Connection |
Rc female thread |
Changes to the R male thread
combination with R male thread is also available. |
Heatproof temperature |
Maximum 60 ℃ |
Heat-resistant (up to 100 ℃) are also available. |
Breakdown |
1MPa |
The breakdown voltage specification (maximum 5MPa) are also available. |
Maximum working voltage |
DC, AC 300V |
Maximum current |
DC, AC 0.5A |
Contact capacity |
50VA |
Material
quality |
Transparent tube |
acrylic |
Heat resistance and breakdown voltage specification product will be the brass tube (C3604).
Heat resistance and breakdown voltage specification product can not be visually float. |
Protective cover |
BC (gunmetal) |
Aluminum can also be manufactured. |
Fittings |
C3604 (brass) |
Made of SUS are also available. |
spring |
SUS304 |
- |
Magnet containing float |
Aluminum |
- |
O-ring |
Nitrile rubber |
Heat resistance and breakdown voltage specification will be the fluorine rubber. |
Reed switch |
Commercial goods |
- |
Lead
(standard 200mm) |
Commercial goods |
Designation of the length of the lead,
it is also possible to change to the cab tire cord. |
|
Caution on the flow switch use
1.
Notes on the magnetic impact
● reed switch, since the switch acting on a magnetic, used where not affected by the magnetic field, please.
● When the magnetic material of iron such as in the vicinity of the reed switch is present, it becomes the cause of the malfunction.
2.
Notes on the electrical connection
● flow switch, it is an over-current flows through the reed switch in the cause, such as a ground wire connection failure as no
Please note the connection.
● Please use as much as possible the alarm detector flow switch.
When used in conjunction with other electrical equipment, over the full consideration the effect when the malfunction occurs, please handling.
● use voltage, when used in suppressing the current used is as small as possible, the life of the reed switch is long Masu no longer.
(Usually 100V0.5A about under the circumstances 100Million times switch actuation available)
3.
Notes on switch actuation due to a change in temperature, change in viscosity of the oil
● of the oil temperature, the viscosity is changed, or if the switch of the switch at a flow rate of the setting does not workOperating flow rate
may change.